Detail Hioki PW-3198
Verify power problems in accordance with the IEC61000-4-30 Class A standard
High Accuracy and continuous gapless recording ( V: ± 0.1% of nominal voltage, A and W: ± 0.2% rdg. ± 0.1% f.s.)
CAT IV 600 V - safe enough for incoming power lines
Broadband voltage range lets you measure even high-order harmonic components of up to 80 kHz
Wide dynamic range from low voltages up to 1300 V ( 3P4W line-to-line voltage)
Maximum 6000 V transient overvoltage up to 700 kHz
LAN, USB and SD card interfaces
Optional GPS BOX for synchronizing multiple devices
For best value, order PRO kit versions which include current clamps, software, and a hard case
Record and Analyze Power Supply Problems Simultaneously with a Single Unit.
The 3198 can measure all waveforms of power, harmonic, and error events simultaneously. When a problem occurs with the equipment or system on your site, the PW3198 will help you detect the cause of the problem early and solve it quickly.
Basic specifications
Measurement line type Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel ( must be synchronized to reference channel during AC/ DC measurement)
Voltage ranges Voltage measurement: 600.00 V rms
Transient measurement 6.0000 kV peak
Current ranges 500.00 mA to 5.0000 kA AC ( depends on each current sensors)
Basic accuracy Voltage: ± 0.1% of nominal voltage
Current: ± 0.2% rdg. ± 0.1% f.s. + current sensor accuracy
Active power: ± 0.2% rdg. ± 0.1% f.s. + current sensor accuracy
Measurement items
Transient overvoltage: 2MHz sampling.
Frequency cycle: Calculated as one cycle, 40 to 70Hz
RMS voltage/ RMS current refreshed each half-cycle
Voltage swell, Voltage dips, Voltage interruption
Inrush current
Voltage waveform comparison
Instantaneous flicker value: As per IEC61000-4-15
Frequency: Calculated as 10 or 12 cycles, 40 to 70Hz
10-sec frequency: Calculated as the whole-cycle time during the specified 10s period, 40 to 70Hz
Voltage waveform peak, Current waveform peak
Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor ( negative-phase, zero-phase)
High-order harmonic component ( voltage/ current) : 2kHz to 80kHz
Harmonic/ Harmonic phase angle ( voltage/ current) , Harmonic power: 0th to 50th oders
Harmonic voltage-current phase angle: 1th to 50th orders
Total harmonic distortion factor ( voltage/ current)
Inter harmonic ( voltage/ current) : 0.5Hz to 49.5Hz
K Factor ( multiplication factor)
IEC Flicker, ” V10 Flicker