Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Barat

Bergabung Selama :

BAGIKAN :   

Bagikan :

Hioki PW-3198

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Hioki PW-3198

Verify power problems in accordance with the IEC61000-4-30 Class A standard High Accuracy and continuous gapless recording ( V: ± 0.1% of nominal voltage, A and W: ± 0.2% rdg. ± 0.1% f.s.) CAT IV 600 V - safe enough for incoming power lines Broadband voltage range lets you measure even high-order harmonic components of up to 80 kHz Wide dynamic range from low voltages up to 1300 V ( 3P4W line-to-line voltage) Maximum 6000 V transient overvoltage up to 700 kHz LAN, USB and SD card interfaces Optional GPS BOX for synchronizing multiple devices For best value, order PRO kit versions which include current clamps, software, and a hard case Record and Analyze Power Supply Problems Simultaneously with a Single Unit. The 3198 can measure all waveforms of power, harmonic, and error events simultaneously. When a problem occurs with the equipment or system on your site, the PW3198 will help you detect the cause of the problem early and solve it quickly. Basic specifications Measurement line type Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel ( must be synchronized to reference channel during AC/ DC measurement) Voltage ranges Voltage measurement: 600.00 V rms Transient measurement 6.0000 kV peak Current ranges 500.00 mA to 5.0000 kA AC ( depends on each current sensors) Basic accuracy Voltage: ± 0.1% of nominal voltage Current: ± 0.2% rdg. ± 0.1% f.s. + current sensor accuracy Active power: ± 0.2% rdg. ± 0.1% f.s. + current sensor accuracy Measurement items Transient overvoltage: 2MHz sampling. Frequency cycle: Calculated as one cycle, 40 to 70Hz RMS voltage/ RMS current refreshed each half-cycle Voltage swell, Voltage dips, Voltage interruption Inrush current Voltage waveform comparison Instantaneous flicker value: As per IEC61000-4-15 Frequency: Calculated as 10 or 12 cycles, 40 to 70Hz 10-sec frequency: Calculated as the whole-cycle time during the specified 10s period, 40 to 70Hz Voltage waveform peak, Current waveform peak Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor ( negative-phase, zero-phase) High-order harmonic component ( voltage/ current) : 2kHz to 80kHz Harmonic/ Harmonic phase angle ( voltage/ current) , Harmonic power: 0th to 50th oders Harmonic voltage-current phase angle: 1th to 50th orders Total harmonic distortion factor ( voltage/ current) Inter harmonic ( voltage/ current) : 0.5Hz to 49.5Hz K Factor ( multiplication factor) IEC Flicker, ” V10 Flicker
Tampilkan Lebih Banyak