Detail Hioki 3455-01
Measure insulation of high-voltage equipment ( such as transformers, cables, and motors)
Adjustable testing voltage ( 250 V DC to 5.00 kV ) in 25 V steps up to 1 kV, and 100 V steps from 1 kV to 5 kV
Step voltage testing, temperature compensation, temperature measurement, and leakage current display
Automatically calculate and display PI ( Polarization Index) and DAR ( Dielectric Absorption Ratio)
Wide measurement insulation range, up to 5 T© ( at 5 kV testing voltage, 1 T© = 1012 © )
Data storage and USB interface
Large, Easy to Read Display
Maximum 5kV Test Voltage - Up to 5T© of Insulated Resistance Testing
The 3455 can generate test voltages ranging from 250 V to 5 kV. Settings can be made in steps as fine as 25 V. Very high insulation resistance measurement up to 5 teraohms is possible.
Ideal for All Insulation Diagnostic Applications
Functions such as automatic calculation and display of PI ( Polarization Index) and DAR ( Dielectric Absorption Ratio) , as well as step voltage test, temperature compensation, temperature measurement, and leakage current display make the 3455 suitable for a variety of diagnostic applications.
Data Memory Function
The 3455 provides a manual storage function for 100 data and a logging function for 10 data ( 360 times) . The date and time of measurement are also recorded.
Basic specifications ( Accuracy guaranteed for 1 year)
Testing voltage 250 V DC 500 V DC 1 kV DC 2.5 kV DC 5 kV DC
Measurement
resistance
organization
( Auto ranging) 0.00M© - 9.99M© ,
9.0M© - 99.9M© ,
90M© - 999M© ,
0.90G© - 9.99G© ,
9.0G© - 99.9G© ,
90G© - 250G© 0.00M© - 9.99M© ,
9.0M© - 99.9M© ,
90M© - 999M© ,
0.90G© - 9.99G© ,
9.0G© - 99.9G© ,
90G© - 500G© 0.00M© - 9.99M© ,
9.0M© - 99.9M© ,
90M© - 999M© ,
0.90G© - 9.99G© ,
9.0G© - 99.9G© ,
90G© - 999G© ,
0.90T© - 1.00T© 0.00M© - 9.99M© ,
9.0M© - 99.9M© ,
90M© - 999M© ,
0.90G© - 9.99G© ,
9.0G© - 99.9G© ,
90G© - 999G© ,
0.90T© - 2.50T© 0.00M© - 9.99M© ,
9.0M© - 99.9M© ,
90M© - 999M© ,
0.90G© - 9.99G© ,
9.0G© - 99.9G© ,
90G© - 999G© ,
0.90T© - 5.00T©
Accuracy
Resistance up to
testing V/ 100 nA ± 5% rdg. ± 5dgt.
0.00M© - 2.50G© ± 5% rdg. ± 5dgt.
0.00M© - 5.00G© ± 5% rdg. ± 5dgt.
0.00M© - 10.0G© ± 5% rdg. ± 5dgt.
0.00M© - 25.0G© ± 5% rdg. ± 5dgt.
0.00M© - 50.0G©
Short current 2 mA Max. 2 mA Max. 2 mA Max. 2 mA Max. 2 mA Max.
Leak current measurement 1.00 nA to 1.20 mA, 6 ranges ( measuring current while testing voltage is generated)
Temperature measurement -10.0 ° C to 70.0 ° C, Accuracy: ± 1.5 ° C
0.0 ° C to 40.0 ° C, Accuracy: ± 1.0° C
( used with the 9631-01/ -05 optional sensor)
Other function Diagnosis insulation, Data storage, PC communication, Elapsed time display, Clock, Average, Data hold, Auto discharge, Auto power-off, etc.
Display Digital LCD, max. 999 dgt. with backlight, Bar graph display
Tampilkan Lebih Banyak